A mixer with a special 3D rotary vane design always produces the same pressure drop over the entire control range at different volume flows. This achieves a high control quality. This can be recognized by a quiet servomotor that can control a constant flow temperature even at low volume flows....
FAQ Category: Heating
FAQ heating
What does GEG compliant thermal insulation mean ?
Pipes and fittings must be insulated at 50% of their nominal diameter at junctions, crossings and central manifolds in accordance with the Building Energy Act (GEG). For heating circuit groups, this means a fully enclosing minimum wall thickness and separation of the flow and return lines. The Tuxhorn tubra®-PGM/PGR pump...
How do you manually open the gravity brake in the ball valve ?
By turning 45°, the gravity brake integrated in the ball valve can be set up manually.
Is it possible to convert the flow from right to left on tubra heating circuit groups ?
Yes, for DN25 and DN32 heating circuit groups, the flow can be converted from left to right on site without any additional accessories required. Bei den DN40 Heizkreisgruppen ist ein Umbauset erforderlich.
How is the tubra®-mag-jet magnetite separator integrated into the heating circuit stations ?
Instead of the pump compensating pipe, the tubra®-mag-jet is installed in the return pipe of the heating circuit station. The required construction length of the tubra® mag-jet results from the dimension of the mounted heating circuit group. This applies to both mixed and unmixed heating circuit stations.
What is the best way to equip a tubra® heating circuit station with a heat meter ?
Tuxhorn offers a heat meter set for heating circuit stations. The scope of delivery includes transition nipples for the installation of a heat meter in the return of the heating circuit station (instead of the pump compensating pipe) as well as a T-piece including sensor adapter for the installation of...